Below are all the network port requirements and visual schematics for your Mividas installation. Port requirements may vary slightly based on the specific Mividas products included.
For information on component isolation and alternative network topologies, refer to Network Schematics.
Network Ports
The following tables provide details on services and required port configurations.
Public Services
Service | Incoming (TCP) |
---|---|
Web UI, feedback events, CMS CDR events, Pexip Eventsink, API requests | 443 (multiple hostnames) |
Browser redirect to HTTPS, feedback events, and passive provisioning for non-TLS endpoints | 80 (optional) |
Rooms mail invite events | 25 or 587 (optional, configurable) |
Rooms Proxy client | 2222 (optional, configurable) |
Internal/Operational Services
Service | Incoming (TCP) |
---|---|
Installer Web UI | 8999 (filtered by firewall, admin only) |
Low-level troubleshooting | 22 (filtered by firewall, admin only) |
Outbound Connections
Purpose | Outbound Port |
---|---|
Package/software download, OS updates | 80, 443, 53 (TCP/UDP) to public internet |
API requests to CMS, VCS, Pexip | 443 (configurable) |
LDAP | 389 / 636 (configurable) |
Mail notifications, invites | 25/587 (configurable) |
External streaming/recording providers | 443 (optional) |
SAML login authorization | 443 (optional, configurable) |
SMS provider (e.g., MoSMS, Sendinblue) | 443 (optional) |
Electronic ID provider (e.g., Swedish BankID) | 443 (optional) |
TLS Ciphers
SSL ciphers can be configured via Installer > Server Settings > SSL Settings > SSL Mode
. Enabling only modern and secure ciphers (minimum TLS 1.2) will allow the following:
- TLS_ECDHE_ECDSA_WITH_AES_128_GCM_SHA256
- TLS_ECDHE_RSA_WITH_AES_128_GCM_SHA256
- TLS_ECDHE_ECDSA_WITH_AES_256_GCM_SHA384
- TLS_ECDHE_RSA_WITH_AES_256_GCM_SHA384
- TLS_ECDHE_ECDSA_WITH_CHACHA20_POLY1305
- TLS_ECDHE_RSA_WITH_CHACHA20_POLY1305
A compatibility setting can be used for legacy conferencing systems without TLS 1.2, though it may reduce security.
Visual Network Schematics
The visual schematics below illustrate network port configurations for different Mividas installations.
Mividas Core

Mividas Rooms

Active Connection via LAN/DMZ with Mividas Proxy
Optional setup

Mividas Core + Mividas Rooms

Mividas Core + Mividas Rooms + Mividas Identify